Please enable JavaScript to view this site.

Navigation: ProAccess Space Configuration

Step 2 - Configure Salto Network

Scroll Prev Top Next More

 

With Salto ProAccess Space open, navigate to System -> Salto Network
 

It will open the Salto Netwok panel.

 

Configure Salto Network - step 2

 

 

The next step is to configure the inputs of the control unit the camera board has been wired into.

 

In the Salto Network panel you will see the CU42E0 gateway,

Click the arrow on the left to drop the tree down now you will see the node (see screenshot below).

 

Double click the node to open its settings

 

Configure Salto Network - step 2_2

 

 

Now define the inputs on the control unit so they are configured to take a third party reader;

 

1.(Yellow bounding box in below screen shot)
In case the Salto wall reader is not required Reader 1 is set to none, configure this according to your setup.
Leave the reader enabled if the Salto wall reader is required.

 

Configure Salto Network - step 2_3

 

 

Double click input 5 (the green line in the above screenshot)

It will open the "Edit input" pop up.
 

1.Under "Type" select Third party reader, this will automatically use input 6 as well and will inform you it’s doing so.

2.Under "Access point number" Select which access point  in the control unit this will relate to.

3.Under Entry/Exit define if it’s an entry or exit reader.

4.Under "Third party reader" select the third party configuration that was set up previously (in this example it is called Wiegand 26).  

5.Click OK

 

Like below

 

Configure Salto Network - step 2_4