Before proceeding please check which Module-X model is being connected.
This chapter is about Module-X3 [GK_MX3]
The Module-X comes with a pigtail existing of:
1.I/O cable
2.Ethernet cable

Module-X3 with dual pigtail
To connect the Symmetry controller, follow the schematic below:
•D0 → D0 terminal
•D1 → D1 terminal
•GND → Common ground
The Module X3 may come with different harness colour variants, but this has no impact on the Wiegand wiring.
The Wiegand signal wires (D0, D1, and GND) are consistently coloured across both versions, so you can safely follow the standard colour coding in the schematic.
If other wires differ in colour, this is expected and does not affect the Wiegand connection.
Below are the two tables for your reference.
Version V4 - I/O cable v4- AV0017-04 -TRVVSP *7P+F+AL +B OD:8. 7±0.2mm |
|||
|---|---|---|---|
P1 |
Color |
Description |
|
1 |
orange |
RS485- (B) |
OSDP |
2 |
white/red |
Wiegand D0 |
|
3 |
black |
Relay_B COM |
|
4 |
white/black |
Relay_A NO |
|
5 |
red |
Wiegand D1 |
|
6 |
black/orange |
RS485+ (A) |
OSDP |
7 |
brown |
GND |
|
8 |
black/brown |
Relay_B NO |
|
9 |
blue |
Relay_A COM |
|
10 |
black/blue |
CTL IN1 |
>2.2=high |
11 |
green |
GND |
|
12 |
black/green |
GND |
|
13 |
yellow |
EXT power in |
24VDC~48VDC |
14 |
black/yellow |
EXT power in |
24VDC~48VDC |
Version V2 - I/O cable v2 - AV0017-02 - TRVVPS 7x2x02m2 |
|||
|---|---|---|---|
P1 |
Color |
Description |
|
1 |
orange |
RS485- (B) |
OSDP |
2 |
white/red |
Wiegand D0 |
|
3 |
black |
Relay_B COM |
|
4 |
white/black |
Relay_A NO |
|
5 |
red |
Wiegand D1 |
|
6 |
black/orange |
RS485+ (A) |
OSDP |
7 |
brown |
GND |
|
8 |
black/brown |
Relay_B NO |
|
9 |
blue |
Relay_A COM |
|
10 |
white/blue |
CTL IN1 |
>2.2=high |
11 |
green |
GND |
|
12 |
white/green |
GND |
|
13 |
yellow |
EXT power in |
24VDC~48VDC |
14 |
black/yellow |
EXT power in |
24VDC~48VDC |