Before proceeding please check which Module-X model is being connected.

This chapter is about Module-X4 [GK_MX4]

 

Module-X with pigtail:

 

The Module-X comes with a pigtail existing of:

 

1.I/O cable

Version: v5- AV0017-04 -TRVVSP *7P+F+AL +B OD:8. 7±0.2mm

2.Ethernet cable

hmfile_hash_9b4f540b

Module-X4 with dual pigtail

 

 

 

 

Wiring diagram of the Module-X4 - I/O cable

 

To connect the Symmetry controller, adhere to the following schematic.

 
Make sure to establish connections to D0, D1, Wiegand GND in and Wiegand +12V in.

 

P1

Color

Description

 

1

orange

RS485- (B)

OSDP

2

white/red

Wiegand D0

 

3

black

Relay_B COM

 

4

white/black

Relay_A NO

 

5

red

Wiegand D1

 

6

black/orange

RS485+ (A)

OSDP

7

brown

GND

 

8

black/brown

Relay_B NO

 

9

blue

Relay_A COM

 

10

black/blue

CTL IN1

>2.2=high

11

green

GND

 

12

black/green

Wiegand GND in

 

13

yellow

EXT power in

24VDC~48VDC

14

black/yellow

Wiegand +12V in